| Daylight & Views - EQc8 |
|
Intent |
To provide building occupants with a connection between indoor spaces and the outdoors through
the introduction of daylight and views into the regularly occupied areas of the building
|
|
Requirements |
Daylight 75% of Spaces - Demonstrate through computer simulations that 75% or
more of all regularly occupied spaces areas achieve daylight illuminance levels of a
minimum of 250 Lux (25 foot-candles (fc)) in a clear
sky condition on September 21 at noon, excluding any areas where tasks are hindered by daylight
Views for 90% of Spaces - Achieve a direct line-of-sight to the outdoor
environment via vision glazing for 90% of building occupants in regularly occupied
areas. Areas adjacent to windows must have a glazing-to-floor area ratio of 0.07 minimum.
Non window-adjacent areas to have a 10 degree horizontal view angle at 1.27M for 50% of
floor area for entire room area to qualify. Exceptions considered on their merit
|